Equipment portfolio
REXGEAR
Electrical safety, power and environmental test equipment.
REXGEAR serves automotive, new-energy, battery and test-lab industries with testing power supplies, regenerative power systems, battery cyclers, environmental test chambers, EMC chambers and more.

REXGEAR's represented range combines electrical safety tests with environmental validation. Choose the electrical function or physical stress first, then define test limits, fixtures, channels and records for the product being evaluated.
Solutions
- Test & measurement equipment
- Environmental testing
REXGEAR · 01 / 02
Test & measurement equipment
Safety and power testing for new energy.
Hipot, insulation and ground-bond testers alongside power systems for battery, motor, inverter, fuel-cell, LED driver and powertrain testing.

ES9005-150-8
Scanning hipot tester, 8 channels (AC/DC/IR)
Eight-channel scanning for programmed AC/DC withstand and insulation-resistance test sequences.
View product online| Technical information | |
|---|---|
| AC hipot maximum | 5 kV @ 30 mA |
| DC hipot maximum | 6 kV @ 10 mA |
| AC capacity | 150 VA |
| Channel arrangement | 8-channel scanning |
Applications
- Sequence dielectric-withstand tests across several isolation points in a multi-output power assembly.
- Check insulation resistance at several fixture contacts on a transformer assembly.
Does the ES9005-150-8 energize all eight positions independently?
REXGEAR lists this model as an eight-channel scanning unit. Map the test points and their order to the scanner, and check whether the combined sequence fits the station’s cycle time.
What outputs do I check before specifying the scanning fixture?
Compare the sequence with the published AC withstand capability of 5 kV at 30 mA, DC withstand of 6 kV at 10 mA and the specified insulation-resistance range. Use the product test procedure for test settings and acceptance limits.

ES9005-150-1
Hipot tester (AC/DC/IR)
AC/DC withstand and insulation-resistance testing.
View product online- Single-channel AC/DC withstand and insulation-resistance testing
| Technical information | |
|---|---|
| AC hipot maximum | 5 kV @ 30 mA |
| DC hipot maximum | 6 kV @ 10 mA |
| AC capacity | 150 VA |
Applications
- Verify primary-to-secondary dielectric withstand on a transformer test bench.
- Run dielectric-withstand and insulation-resistance checks on a power assembly with one test connection per step.
Why select the ES9005-150-1 over the 100 VA single-channel version?
The 150 VA model is rated for 5 kV AC at 30 mA, compared with 20 mA on the 100 VA model. Review the AC current capability called for by your procedure at the required voltage.
Can the withstand sequence use a defined voltage ramp?
REXGEAR lists adjustable ramp-up, test and ramp-down times on the ES9005-150-1. Use the values defined for your product, and confirm the fixture and interlocks for the setup.

ES9005-100-1
Hipot tester (AC/DC/IR)
Single-channel AC/DC withstand and insulation-resistance testing.
View product online- Single-channel model with lower AC output-current capacity than ES9005-150-1
| Technical information | |
|---|---|
| AC hipot maximum | 5 kV @ 20 mA |
| DC hipot maximum | 6 kV @ 10 mA |
| AC capacity | 100 VA |
Applications
- Check dielectric withstand between mains conductors and isolated circuitry on a small power supply.
- Measure insulation resistance at a single configured isolation point in an electrical subassembly.
How do I decide whether the ES9005-100-1 fits my AC test?
REXGEAR rates it at 5 kV AC and 20 mA. Check the test voltage and required AC current capability against the instrument rating at the operating point.
Can the same ES9005-100-1 perform an insulation-resistance test?
Yes. Select the insulation-resistance function and confirm the test voltage and resistance limits from the product procedure against the instrument’s published ranges.

EG9200 series
Protective-earth bond resistance tester
Ground-bond resistance measurement using the current, duration and acceptance limits defined by the product test procedure.
View product online- Four-terminal measurement and programmable test files for ground-bond procedures
| Technical information | |
|---|---|
| Test current | 1.00–45.00 A |
| Protective-earth bond resistance range | 0–600 mΩ |
Applications
- Measure the protective-earth bond from an appliance inlet to an exposed metal chassis.
- Check the bond of a production cabinet door or grounding strap to the cabinet’s protective-earth point.
Why does the EG9200 use four-terminal measurement?
Separate force and sense connections reduce the effect of test lead resistance when measuring a low-resistance bond. Locate the sense contacts at the endpoints defined by the test procedure.
How do I select the ground-bond test current?
Start with the specified test current, duration and resistance limit for the product. Match them to the EG9200 variant and confirm the fixture can make repeatable contact on the actual enclosure.
Testing applications
- Battery charge/discharge testing
- Battery cell & pack testing
- Electric motor testing
- New-energy grid inverter testing
- Hydrogen fuel cell testing
- LED driver testing
- Powertrain testing / battery emulation
Applications & selection
Hipot checks dielectric withstand; insulation-resistance testing measures insulation; ground-bond testing measures resistance of the protective-earth path. ES9005 combines AC/DC hipot and IR; EG9200 uses four-terminal ground-bond measurement.
Where it fits
- Production or laboratory safety testing of electrical equipment and assemblies
- Multi-point insulation and protective-earth verification
What to consider when selecting
- Choose AC voltage/current capability from the test requirement: the 150 VA single-channel version provides 5 kV at 30 mA; the 100 VA version provides 5 kV at 20 mA.
- The ES9005-150-8 is an eight-channel scanning tester. Scanning should not be interpreted as eight independent simultaneous sources.
- Define limits, test duration, fixture contacts and operator interlocks from the applicable product test procedure; instrument ratings alone do not establish a pass/fail requirement.
REXGEAR · 02 / 02
Environmental testing
Define the product's environmental test program.
Review temperature/humidity, vibration, EMC and battery-test chamber categories against a defined test procedure. Specify each system's usable envelope and protection configuration separately.

Chambers & systems
- Temperature / humidity chambers
- Battery cell tester chambers
- Battery explosion-protection chamber category; configuration must be specified
- Vibration test solutions
- EMC test chambers
- Xenon lamp aging chambers
Applications & selection
Environmental test equipment applies controlled stresses such as temperature/humidity, vibration or weathering. The represented chamber categories also include battery-test, explosion-protection and EMC arrangements; each needs a project-specific configuration.
Where it fits
- Product reliability qualification and temperature/humidity exposure
- Battery-cell testing and product-specific EMC or vibration programs
What to consider when selecting
- Provide specimen dimensions, mass, heat dissipation and required temperature/humidity profile before sizing a chamber.
- Battery testing requires defining electrical feedthroughs, cell monitoring and the intended failure scenario with the chamber configuration.
- Specify the EMC method, vibration profile or xenon exposure procedure explicitly; no chamber limits are published here because no exact chamber model is identified.
Common questions
When is an eight-channel scanning hipot tester useful?
It helps address several connection points in a programmed test sequence. Confirm wiring and channel sequencing; the manufacturer's scanning configuration is distinct from its independent-channel products.
Does hipot replace a ground-bond test?
They evaluate different electrical paths. ES9005 covers withstand/insulation functions; EG9200 supplies higher test current for protective-earth resistance measurement. Select the functions required by the product procedure.
What is needed for an environmental-chamber proposal?
Supply the applicable test procedure, specimen details, environmental profile, measurement/feedthrough needs and expected failure conditions. REXGEAR lists several chamber categories; the category alone does not specify usable volume, range or safety configuration.
Documentation & references
Images illustrate products or families; they do not establish the revision or accessories of quoted equipment. Capabilities and options depend on configuration and process conditions. Confirm requirements with an applications engineer.
- ES9005 single-channel safety testershttps://rexgear.com/pages/safety-testers
- ES9005 scanning and independent-channel testershttps://rexgear.com/pages/safety-testers-multi-channel
- EG9200 ground-bond specificationshttps://rexgear.com/products/eg9200-series-ground-bond-tester
- Official testing and chamber portfoliohttps://rexgear.com/pages/about-us-2
- ES9005-150-8 technical specificationshttps://rexgear.com/products/es9005-150-8-safety-tester
- ES9005-150-1 technical specificationshttps://rexgear.com/products/es9005-150-1-safety-tester
- ES9005-100-1 technical specificationshttps://rexgear.com/products/es9005-100-1-safety-tester