Test & measurement equipment
ES9005-150-8
Scanning hipot tester, 8 channels (AC/DC/IR)
Eight-channel scanning for programmed AC/DC withstand and insulation-resistance test sequences.

ES9005-150-8
Technical information
- AC hipot maximum
- 5 kV @ 30 mA
- DC hipot maximum
- 6 kV @ 10 mA
- AC capacity
- 150 VA
- Channel arrangement
- 8-channel scanning
Capabilities and options depend on configuration and process conditions. Confirm your requirements with an applications engineer.
Applications
- Sequence dielectric-withstand tests across several isolation points in a multi-output power assembly.
- Check insulation resistance at several fixture contacts on a transformer assembly.
Other models in this family
Common questions
Does the ES9005-150-8 energize all eight positions independently?
REXGEAR lists this model as an eight-channel scanning unit. Map the test points and their order to the scanner, and check whether the combined sequence fits the station’s cycle time.
What outputs do I check before specifying the scanning fixture?
Compare the sequence with the published AC withstand capability of 5 kV at 30 mA, DC withstand of 6 kV at 10 mA and the specified insulation-resistance range. Use the product test procedure for test settings and acceptance limits.
Explore further
Documentation & references
Use the references for each solution to explore further. Talk to our sales team about the configuration, accessories and requirements for your application.
Images illustrate products or families; they do not establish the revision or accessories of quoted equipment.
Let’s discuss your application
Share your requirements to evaluate the right configuration.