Equipment portfolio
ITECH
Programmable power instruments
ITECH is a global manufacturer of programmable power instrumentation: AC/DC power supplies, electronic loads, battery simulators, grid simulators and automated test systems for power electronics, automotive, renewable energy and semiconductors.

- IT6600D parallel-system maximum, configuration dependent
- 10 MW
- Solution groups shown
- 4
ITECH's represented instruments cover battery cycling, programmable AC/DC excitation and precision source/measurement. Specify what must source power, absorb power or measure a device, then choose the operating envelope and channel arrangement.
Solutions
- Power test portfolio
ITECH · 01 / 01
Power test portfolio
From the bench to megawatts.
Battery charge/discharge systems, programmable AC sources, high-power DC supplies and precision source-measure units.

ITS5300
Battery charge & discharge test system
An integrated charge and discharge test system for battery validation.
View product online- Configured channels for charge/discharge tests, auxiliary measurements and battery communications
- Current brochure describes regenerative energy return and drive-cycle simulation; final ratings depend on system configuration
Applications
- Measure discharge capacity of battery modules at defined points in a life-cycle test.
- Replay a drive-cycle profile on a battery pack while recording the configured electrical and temperature channels.
What data do we need to size an ITS5300 channel for a pack?
Provide the pack voltage window, charge and discharge current, pulse duration and number of parallel test stations. Specify any temperature and internal-resistance measurements the test sequence needs.
Can the ITS5300 monitor signals from the pack’s battery management system?
ITECH documents battery management system communication in supported setups. Provide the required messages, stop conditions and thermal monitoring so the system can be configured and validated for your pack.

Programmable AC power supplies
IT7300 · IT7600 · IT-M7700
Programmable AC sources IT7300, high-performance AC supplies IT7600 and compact IT-M7700. Select voltage, frequency, phase and power requirements for the device under test.
View product online- IT7300 and IT-M7700 offer programmable AC test conditions; verify the exact voltage, frequency and VA/current capability
- IT-M7700 includes power metering. The official family table excludes IT-M7721L/IT-M7722L from arbitrary waveform output; confirm the exact model revision.
Applications
- Evaluate whether an AC/DC adapter recovers after a specified input-voltage dip.
- Check the startup behavior of a line-powered product at multiple voltage and frequency points.
Can any IT-M7700 variant generate an arbitrary waveform?
ITECH excludes arbitrary waveform output on IT-M7721L and IT-M7722L in its family table. Verify the exact model when the test requires a custom waveform.
What ratings matter if my adapter draws a high startup current?
Check peak and steady-state current, apparent power in VA and the required voltage and frequency together. Use the exact source’s permissible output and peak duration to evaluate the startup profile.

High-power programmable DC supplies
IT6600D · IT6000D · IT-M3900D
Compare IT-M3900D, IT6000D and IT6600D by the required voltage/current operating points. Multi-megawatt figures refer to configured parallel systems rather than one compact instrument.
View product online- High-power DC source families; specify load absorption separately if the DUT returns energy
| Technical information | |
|---|---|
| IT6600D | 21 kW/channel example; 42 kW combined in 3U; larger configured systems |
| IT6000D | Model dependent; parallel systems up to 2 MW |
| IT-M3900D | 1.7–12 kW family; select voltage/current model |
Applications
- Supply a DC/DC converter over a battery-bus voltage window during verification.
- Set repeatable DC supply points for an inverter input-stage test.
When can a 3U IT6600D deliver 42 kW?
ITECH describes a dual-channel unit rated at 21 kW per channel, with 42 kW when the channels are combined in a supported connection. Verify the specific connection and output envelope at every required operating point.
What if the device sends current back to the DC supply?
Specify both sourcing and sinking requirements, including the magnitude and duration of returned power. Verify the selected configuration’s ability to absorb energy or size a separate electronic load.

Source measure & analysis
IT2800 · IT2705
The IT2800 high-precision graphical source measure unit (SMU) and the IT2705 modular DC power analyzer.
View product online- IT2800 supports four-quadrant I–V characterization; voltage/current ranges depend on the selected SMU
- IT2705 supports up to eight configured channels with modules from 20 W to 500 W, plus waveform sampling and logging
Applications
- Sweep voltage and measure current to plot a semiconductor device’s I–V curve with an IT2800.
- Capture DC/DC converter startup and transient response with source and load modules in an IT2705.
Which instrument suits a transistor characterization bench?
Consider IT2800 for precision source and measurement sweeps. Specify the required voltage, current and compliance limits, then verify how many channels the device setup needs.
How do I configure an IT2705 for a converter startup test?
Define the DC source for the converter input and the load module for its output. Check each module’s voltage, current and power limits and the sampling needed to resolve the startup waveform.
Applications & selection
A programmable source applies controlled electrical conditions to a device; a battery system coordinates charge/discharge and measurements; an SMU combines sourcing and sensing for electrical characterization. These functions need different power, accuracy and timing specifications.
Where it fits
- Battery module/pack capacity, aging and drive-cycle validation
- AC input variation and high-power DC device testing
- Semiconductor I–V characterization and dynamic low-power device analysis
What to consider when selecting
- Give voltage, current and power at the same operating points. A series' maximum voltage, maximum current and maximum power are not necessarily available simultaneously.
- Separate a stand-alone instrument rating from a paralleled system rating. IT6600D's 3U example has two 21 kW channels or 42 kW combined; larger systems require the specified configuration.
- For automated tests, define channel independence, transient speed, data sampling, protection interlocks and the required communication interface before selecting instruments.
Common questions
Is a power supply the same as a battery cycler?
A cycler must manage both charging and discharging with the required monitoring and protection. ITS5300 is configured as a battery test system; specify module/pack voltage, current, channels, temperature acquisition and BMS communications together.
When should I compare an SMU with a DC power analyzer?
Use IT2800 for precision source/measurement and I–V characterization. IT2705 combines configurable modules with waveform viewing and logging for multi-channel dynamic tests; its capabilities depend on installed modules.
What should an AC-source enquiry specify?
Include voltage, frequency, VA/W demand, startup current and waveforms. The official IT-M7700 family table marks IT-M7721L/IT-M7722L as excluding arbitrary waveform output. Confirm the exact revision and supported waveforms before selecting.
Documentation & references
Images illustrate products or families; they do not establish the revision or accessories of quoted equipment. Capabilities and options depend on configuration and process conditions. Confirm requirements with an applications engineer.
- ITS5300 battery test systemhttps://www.itechate.com/en/product/test-system/ITS5300.html
- ITS5300 regenerative module/pack testing brochurehttps://www.itechate.com/uploadfiles/catalogue/ITS5300-en.pdf
- IT-M7700 AC sourceshttps://www.itechate.com/en/product/ac-power-supply/IT-M7700.html
- IT7300 programmable AC sourceshttps://www.itechate.com/en/product/ac-power-supply/IT7300.html
- IT6600D power and channel configurationshttps://www.itechate.com/en/product/dc-power-supply/IT6600D.html
- IT6000D output and parallel operationhttps://www.itechate.com/en/product/dc-power-supply/IT6000D.html
- IT2800 graphical SMUhttps://www.itechate.com/en/product/SMU/IT2800.html
- IT2705 modular DC power analyzerhttps://www.itechate.com/en/product/dc-power-supply/IT2705.html
- Official product-family indexhttps://www.itechate.com/en/product.html
- IT7600 programmable AC sourceshttps://www.itechate.com/en/product/ac-power-supply/IT7600.html
- IT-M7700 selection tableshttps://www.itechate.com/uploadfiles/catalogue/IT-M7700-en.pdf
- IT2705 modules and test configurationshttps://usa.itechate.com/uploadfiles/catalogue/IT2705-en.pdf