Equipment portfolio
Specialty Coating Systems
Conformal coating and curing
SCS supplies automated coating and dispensing platforms, UV curing equipment and Ionograph ionic-contamination test systems. Define application, cure and cleanliness criteria separately.

Connect selective material application, the correct cure process and ionic-cleanliness monitoring.
Solutions
- Coating, curing & testing
Specialty Coating Systems · 01 / 01
Coating, curing & testing
Application, curing and ionic-contamination measurement.
Use coating/dispensing equipment, compatible UV curing and ionic-contamination testing for their respective process tasks. Agree on material-specific curing and quality acceptance criteria.

PrecisionCoat VI
Configurable selective coating and dispensing
PrecisionCoat VI is a programmable coating, dispensing and potting platform. It has three standard axes; tilt/rotate axes, vision, height mapping and AQC tool change are configuration options.
View product online- Optional AQC accommodates up to eight configurable valves/tools.
| Technical information | |
|---|---|
| Substrate size, minimum to maximum | 2 × 2 → 20 × 20 in / 5.08 × 5.08 → 50.8 × 50.8 cm |
| Substrate clearance above/below pass line | 5 in / 13 cm |
| Standard axes | 3; optional 4th/5th axes |
Applications
- Apply selective conformal coating while leaving connector contact areas open.
- Dispense potting compound into an electronics enclosure using material-specific metering and mixing.
When should I specify tilt and rotation on PrecisionCoat VI?
SCS offers programmable five-axis tilt and rotation as an option. Assess it where tall components restrict access at a vertical angle. Verify film coverage and clearance at nearby connectors on a populated board.
Can one PrecisionCoat VI handle coating and two-part potting?
SCS publishes configurations with interchangeable valves or multiple heads and options for one- and two-part materials. Trial your coating and resin to size the valve and mixer and verify purge, shot volume and changeover.

PrecisionCoat BT
Benchtop automation
Automates time-intensive manual coating and dispensing, or adds coating capacity in the laboratory or on the production floor.
View product online- Three-axis motion; the controller stores the last downloaded profile.
| Technical information | |
|---|---|
| Maximum substrate, one valve | 14 × 14 in / 35.6 × 35.6 cm |
| Maximum substrate, two valves | 11.8 × 14 in / 30.0 × 35.6 cm |
| Listed repeatability | ±0.003 in / ±0.08 mm |
Applications
- Automate conformal coating on manually loaded low-volume circuit boards.
- Develop a repeatable dispense pattern for short runs or laboratory builds.
What usable board size changes with two valves?
SCS lists a maximum substrate of 35.6 × 35.6 cm with one valve and 30.0 × 35.6 cm with two. Height above the board also falls from 12.1 to 8.26 cm. Review your fixture and the tallest components.
Can an operator repeat the last coating cycle without a computer at the bench?
The cycle-start button runs the last profile downloaded to the controller. Match the loaded assembly and material to that profile when switching between jobs.

PrecisionCure UVC
Microwave-activated UV curing
Microwave UV curing with programmable profiles; single- or double-sided systems have different lamp arrangements and utilities.
View product online| Technical information | |
|---|---|
| Available irradiated widths | 6.6 / 13.2 / 19.8 in; 16.7 / 33.5 / 50.3 cm |
| Substrate width | 2.5–20 in / 6.5–50.8 cm |
| 80-inch system conveyor speed | 0.5–10 in/s / 13–254 mm/s |
Applications
- Cure a compatible UV conformal coating after selective spray on a circuit-board line.
- Evaluate top- and bottom-side exposure for boards coated on both faces using the double-sided MUV configuration.
Which MUV configuration supports curing on both sides?
SCS offers the 80-inch MUV in single- or double-sided configurations. The 46-inch model supports single-sided curing and uses a moving lamp carriage. Check exposure requirements, lamp coverage and line footprint before selecting a system.
What trial data help specify the UV cure profile?
Get the required spectrum and exposure from the coating supplier. Check the delivered dose at the board surface across the usable width, including areas shadowed by tall parts, while running at the target line speed.

Ionograph® SMD V
Dynamic ionic-contamination measurement
Ionograph SMD V uses dynamic solvent extraction to measure ionic contamination on suitable parts. Specify the extraction method and acceptance criteria; the result alone does not establish total product reliability.
View product online- Four test-cell sizes; review the tapered depth of the first three sizes for part fit.
| Technical information | |
|---|---|
| Estimated solution capacity, configuration dependent | 24.6–56.8 L |
| Maximum temperature with optional heater | 45 °C / 113 °F |
| Machine weight | 173 kg / 382 lb |
Applications
- Trend ionic residues on large printed circuit boards after aqueous or semi-aqueous washing.
- Compare ionic cleanliness from different cleaning or low-residue flux process settings using a defined extraction method.
How should I select an Ionograph SMD V test cell?
SCS lists four cell options. Compare the complete part envelope, including tall components and any test holder, against the width, height and depth at the top and bottom of the cell.
When should a heated extraction be evaluated?
SCS offers heated solution as an option to help extract ionic material in hard-to-reach areas such as under surface-mounted parts. Establish the temperature and extraction conditions with your quality team, then use the same method when comparing process runs.
Applications & selection
PrecisionCoat automates coating and dispensing; PrecisionCure UVC supplies UV exposure; Ionograph measures extractable ionic contamination. Each stage answers a different process requirement and needs its own acceptance criteria.
Where it fits
- Selective conformal coating and dispensing
- UV curing of compatible materials
- Cleanliness monitoring for bare and assembled PCBs
What to consider when selecting
- Supply material data, required coverage/thickness and keep-out areas. Review valve choice and whether tilt/rotate or height mapping is needed.
- Choose the curing configuration from material wavelength/dose requirements, board geometry and shadows; confirm utilities for the exact lamp count.
- For ionic testing, specify part envelope, extraction method and acceptance criteria. A cleanliness measurement does not by itself validate coating thickness or cure.
Common questions
How does PrecisionCoat BT differ from VI?
BT is a compact benchtop platform with up to two valves. VI supports a broader configurable application platform, including optional tilt/rotate and quick tool change. Compare the substrate envelope with the selected valve setup.
Is UVC MUV the same as an arc-lamp or LED system?
MUV uses microwave-activated UV lamps. Identify the required spectrum and exposure profile with the coating supplier before selecting lamps and line speed.
What does the Ionograph SMD V monitor?
It uses a dynamic extraction process to measure ionic contamination and help control cleaning/no-clean processes. Define the extraction and acceptance method with the quality team rather than treating one reading as proof of total reliability.
Documentation & references
Images illustrate products or families; they do not establish the revision or accessories of quoted equipment. Capabilities and options depend on configuration and process conditions. Confirm requirements with an applications engineer.
- PrecisionCoat VI specifications and optionshttps://scscoatings.com/equipment/spray-dispense-systems/precisioncoat/
- PrecisionCoat BT specificationshttps://scscoatings.com/equipment/spray-dispense-systems/precisioncoat-bt/
- PrecisionCure UVC MUV configurationshttps://scscoatings.com/equipment/curing-systems/precisioncure-uvc-muv/
- Ionograph SMD V technical informationhttps://scscoatings.com/equipment/ionic-contamination-test/ionograph-smd-v/
- Ionograph Series manufacturer brochurehttps://scscoatings.com/wp-content/uploads/87-SCS-Ionograph-Series.pdf
- PrecisionCoat VI manufacturer brochurehttps://scscoatings.com/wp-content/uploads/2023/01/22-SCS-PrecisionCoat-VI-0123.pdf
- PrecisionCure UVC MUV manufacturer brochurehttps://scscoatings.com/wp-content/uploads/2024/10/45_SCS_PrecisionCure_UVC_MUV_0824.pdf